Flexible Archives - Everwell Parts, Inc. https://everwellparts.com/product-category/electrical-components/defrost-heater/flexible/ Everwell Parts, Inc. Mon, 12 Jan 2026 21:23:06 +0000 en-US hourly 1 https://everwellparts.com/wp-content/uploads/cropped-everwell-parts-logo-32x32.png Flexible Archives - Everwell Parts, Inc. https://everwellparts.com/product-category/electrical-components/defrost-heater/flexible/ 32 32 FDH-045 – 300W 120V 2.5A 15" Flexible Bend-to-Fit Defrost Heater https://everwellparts.com/product/300w-120v-2-5a-15-flexible-bend-to-fit-defrost-heater-fdh-045/ Mon, 12 Jan 2026 21:23:06 +0000 https://everwellparts.com/product/flexible-bend-to-fit-defrost-heaters-fdh-045/ Part No. FDH-045

For Evaporator coils and condensate drain pans in commercial refrigeration.

Features:

  • Bend and shape easily with hands at job site
  • To replace a coil heater, measure the old heater length and bend our heater to match the configuration of the old heater and install
  • The encapsulated ends on the heaters are water resistant, but should not be submerged in water
  • Quickly replaces most defrost heaters
  • Measure length of original and order a similar length
  • The heaters are 0,250 incoloy which is comparable to alloy 334

Sometimes more than 1 heater is needed to handle a replacement. In that situation, remember the following:

  • Two heaters of equal wattage. Connect in series at rated voltage. This will generate 1/2 the wattage of 1 heater. For example, 2 ea 500W heaters, 230V connected in series to 230V = 250 watts total
  • Two 115V heaters with equal wattage connected in series to 230V power will generate their total wattage. For example, 2 ea 300W, 115V heaters connected in series = 600W total output
  • Two heaters with equal voltage connected in parallel (at rated voltage) will produce the total of their wattages. For example, 1 ea 500W heater and 1 ea 300W heater, both 115V wired in parallel = 800W total
]]>

Part No. Watts Volts Amp Length (in)
Sheath Heated
FDH-045 300 120 2.5 45 31
FDH-068 450 120 3.8 68 54
FDH-091 675 240 2.9 91 77
FDH-105 850 240 3.6 105 91
FDH-118 1,000 240 4.1 118 104
FDH-150 1,350 240 5.7 150 136
FDH-188 1,250 240 5.2 188 174
]]>